Fully Automatic 3-Part 23 Parameters Hematology Analyzer H-7022 Touch Screen
Deskripsi
Deskripsi
Kategori | Uncategorized |
---|
H-7022 Touch Screen 3-Part 23 Parameters Hematology Analyzer (Less Service, More Stable) is a 3-part differential of WBC blood cell counter. Its advantages include digital technology, auto-relocation separatrix, intelligent flush clog, dual measuring technology (with time and volume) to ensure precise test results.
Automated and User-Friendly Interface
- 8-inch LCD display, resolution: 800×600
- Real-time alert for abnormal results
- USB keyboard and mouse operation
- Based on Linux
- Easy to search and edit patient information
- Storage capacity: 50,000 results including histograms
- Optional printout for formats
- Real-time guidelines for easy operation
Accurate Results and Low Sample Consumption
- Accurate analysis technology with low sample consumption
- Venous mode: 9.6ul
- Capillary mode: 9.6ul
- Pre-diluted mode: 20ul
Easy Maintenance and Environmentally-Friendly System
- Adjustable sample probe for various cuvettes
- With liquid sensor to alarm low reagent
- Cyanide-free Lyse
- Automated and Systematic diagnosis and maintenance with alerts
- Liquid tubing and electronic circuit separately for easy maintenance
- Closed reagent tubing to avoid contamination
Perfect QC System
- Calibration mode: manual and auto
- QC mode: L-J, SD, CV, QC histogram
Advanced Technology
- Unique sweep flow technology to avoid recounting
- Auto-relocation separatrix to exact the differential of WBC
- Intelligent PLT histogram fit technology to improve the precision of PLT
- Auto sample probe cleaning
- Auto standby and wakeup
- High voltage burn, soaking and flush clog with real time monitor
Operation Mode: | USB keyboard & mouse. Based on Linux system | ||||||||||||
Parameters: | 3-part differential of WBC; 20 parameters + 3 color histograms (WBC/RBC/PLT) | ||||||||||||
Sample Consumption: | Venous Mode: 9.6µL, Capillary Mode: 9.6µL, Pre-diluted Mode: 20µL | ||||||||||||
Working Mode: | Double passages counting detection + independent HGB measurement system; 24 hours with auto standby | ||||||||||||
Language: | Multi-language supported | ||||||||||||
Throughput: | ≥60 samples/hour | ||||||||||||
Storage: | 50,000 sample results with histograms, record supported export and backup L-J,SD,CV,QC histogram | ||||||||||||
QC mode: | L-J, SD, CV, QC histogram | ||||||||||||
Cross Contamination Ratio: | WBC/RBC/HGB<0. 5%, PLT<1% | ||||||||||||
Performance: |
|
||||||||||||
Display: | 8″ LCD, resolution :800 x 600 | ||||||||||||
Reference Value: | Baby, Kid, Woman, Man, Normal and Customization | ||||||||||||
Interface: | 4 xUSB, 1 x ethernet, 1 x VGA (for external monitor) | ||||||||||||
Printer: | Bulit-in thermal printer, supports external laser and inkjet printer, 5 kinds of report formats supported | ||||||||||||
Environment Requirement: | Temperature: 15°C-35°C; Humidity: 10%-90% | ||||||||||||
Power Supply: | AC100-240V 50/60Hz |