Home » Produk » Fully Automatic Chemistry Analyzer FACA-200

Fully Automatic Chemistry Analyzer FACA-200

  • Deskripsi
  • Deskripsi
    Kategori , ,

    CABINET IS OPTIONAL

    Labomed introduces an automatic chemistry analyzer with varying testing capacities.

    200 tests/hour or 320 tests/hour with ISE

    Labomed Inc. is certified by ISO 9001, CE Conformity and is FDA Licensed.

    Features

    Each set of FACA will come with one video to train in the installation, operation, and maintenance of the biochemistry analyzer.

    System Functions

    Type: Fully Automated, Random Access Biochemistry Analyzer.
    Throughput: 200 tests, up to 320 tests/hr with ISE (optional).
    Test Mode:  End point, Kinetics, Fixed Time, lmmunoturbidimetry, Monochromatic, Bi-chromatic and Multi-Standard Analysis, Linearity and Nonlinearity Calibration, Single and Dual Reagents  can be used.
    Test Setting: Programmable for single-parameter, multi-parameter, combined parameter, batch test.
    Parameter Setting: Completely open for editing test 3ertyuio

    1 parameters and calculation parameters.

    Sample System
    Sample Tray:  44 sample positions for primary tubes, test tubes and various sample cups, Whole sample tray is removable and replaceable. Any position can be aligned as the emergency test position.
    Sample Volume: 3 µL – 30 µL, programmed by 0.1 µL step.
    Sample Handling: Dilute and  retest automatically when the sample’ s concentration is beyond limitation.
    Sample Probe: Liquid level detection and collision protection.
    Probe cleaning:  Automatic washing for both inside and outside, carry over <0.1%.
    Syringe: High performance syringe, durable  and  maintenance free.
    Optional item: Barcode reader.

    Reagent System
    Reagent Tray: 44 positions for Single and Dual reagents, reagent positions can be aligned freely.
    Refrigeration:  Refrigerated reagent compartment, 24 hours non-stop cooling with Peltier element to maintain temperature 4-15 ℃.
    Reagent Bottle Volume: 45ml and 15ml, Slope bottom design.
    Reagent volume:  150 µL – 300 µL, prograrnmed by 0.1µ1 step.
    Reagent Probe: Automatically detecting the liquid level; collision protection.
    Reagent pre-heating function, inventory checking.
    Real time monitoring of reagent residual volume and auto alarm.
    Probe Cleaning:  Washing  for  both  inside and outside, carry over <0. 1%.

    Reaction System
    Reaction Tray: 44 reaction cuvettes with 6mm optical path, good UV penetrability, low consumable, low cost.
    Reaction Technology: Back – Dividing – Light – Technology.
    Reaction Volume: 250 µL – 300 µL.
    Temperature: 37℃, with +0.1℃ fluctuation.
    Mixing System: Independent mixer.
    Cleaning: Supports automatic cleaning of cuvettes and allows for complete drainage to reduce carry over.
    Water consumption: 3L/hour.
    Liquid Detection: Detergent, distilled water, waste liquid automatic detection and alarm.

    Optical  System
    Light Source:  Halogen lamp 6V/ 10W, life span > 3000 hours.
    Wavelength:  340nm, 405nm, 450nm, 492nm, 505ml, 546nm, 578nm, 620nm, 670nm, 700nm
    Wavelength  Accuracy:  +2nm.
    Detector:  Photoelectron Diode Array.
    Absorbance Range: 0.000 Abs -3.000 Abs.

    Calibration and Quality Control
    Calibration Mode:  Linear (one-point, two-point  and rnulti-point ), Logit-Log4P, Logit-Log5P, Spline, Exponential, Polynomial, Parabola.
    QC Rules:  Westgard Multi-rule.
    QC Mode:  Intra-day  and inter-day QC.

    Operating System
    Computer:  Windows 2000 System or above.
    Data Management:  Large capacity for results and reaction curves to be displayed, saved and printed.
    Report: Edit and print complete reports, format editable, supports network printing.
    Port:  RS-232.

    Filters:

    FACA200 will have 10 filters 340,405,450,492,505,546,578,620,670,700nm

    Working  Conditions
    Power: 220V ±22V, 50/60Hz ± 1Hz
    Power Consumption: <400VA
    Environmental    Temperature: 15℃ – 30℃
    Humidity:  <85%
    Dimension: 85x75x75 cm (LxWxH)
    Weight: 145 Kgs

    QC control function, based on Levy-Jennings chart analysis

    This instrument is open system and can use any common brand reagents.

    Accessories (Optional)

    Item Specification
    Quantity
    Reagent bottle 1 40ml 50Pcs
    Reagent bottle 2 with holder 15ml 15Pcs
    Reaction cuvette 80pcs
    Serum Cup 1000pcs
    Tube 1 set
    Fuse(4A/8A) 4 sets
    Lamp(13.8V/50W) 1Pc
    Power cable 1Pc
    Com Cable 1Pc
    User manual Operation software
    Tool 1 set
    Sensor 1Pc
    Detect Probe, 1Pc
    Sample Probe 1Pc
    Ground Cable 1Pc

    (all of these accessories are included with the FACA-200)

    Testing items:
    Acid Phosphatase
    Albumin
    Alkaline Phosphatase (ALP)
    Amylase
    Aspartateamino Transferase – AST (SGOT)
    Alanineamino Transferase – ALT (SGPT)
    Blood Urea Nitrogen
    Bilirubin – Direct
    Bilirubin – Total
    BUN
    C3
    C4
    Ca+ (Calcium)
    Cholesterol
    Chloride (Cl-)
    CK (Creatine Kinase)
    CK-MB
    CO2
    Creatinine
    CSF protein
    GGT (Gamma-Glutamyl Transferase)
    Globulin
    Glucose
    High Density Lipoprotein
    HDL Cholesterol
    Hemoglobin
    IgA
    IgG
    IgM
    Inorganic Phosphorus
    Iron
    K+ (Potassium)
    LDH (Lactate Dehydrogenase)
    LDL Cholesterol
    Lipase
    Low Density Lipoprotein
    Mg (Magnesium)
    Non Esterified Fatty Acid
    Phosphorus (Inorganic)
    Sodium (Na+)
    Total Protein
    Triglycerides
    Urea
    Uric Acid
    Urine protein

    BROCHURE :

    Fully Automatic Chemistry Analyzer FACA-200

    Keranjang belanja

    Tidak ada produk di keranjang.

    Kembali ke toko